Monday, October 16, 2017

InRack and InRow Cooling for Data Center

Traditional data center, computer room, and server room cooling methods cool down an entire room with cold air from centralized units to one end of the room. This approach is acceptable when power densities are minimal with few hot spots in the room. However, room-oriented designs are affected by room constraints including ceiling height, room shape, obstructions above and below the floor, rack layout, Computer room air conditioning (CRAC) units' location, power distribution, etc.




CRAC units force chilled air into a data center and around the equipment. In most cases, cooling these vast volumes of air is very inefficient. Although a hot and cold aisle containment decreases the volume, it still results in a lot of excess cooling and costs of powering the CRACs. 

So why don't consider more selective data center cooling options which work together with your CRAC units or chill specific critical loads with high efficient ways but low energy cost?




Modern data centers adopt InRack and InRow coolers (IRCs), also known as close-coupled cooling systems, because they are tailor-made for high densities of hot-running IT equipment and tight energy budgets. These cooling strategies are inherently more efficient than standard CRAC systems because it ties into the IT equipment rather than sending cooled air into the room space. They may be mounted among the IT racks / cabinets or they may be mounted overhead or under the floor.


InRack Cooling




Dedicated racks, another low-effort retrofit, offer cooling isolation. The rack operates just like a standard data center rack, but it is sealed on all sides as a self-contained system. Cool air is forced up through the rack from the bottom, running over the equipment before exiting through the top to a hot plenum, where the heat is vented or recovered as necessary.




InRow Cooling




In-row cooling systems work within a row of standard server racks. The units are standard rack height, making them easy to match with the row and couple tightly to the IT equipment to ensure efficient cooling. Systems from APC by Schneider Electric, Liebert by Emerson Network Power, Rittal and others are engineered to take up the smallest footprint and offer high-density cooling. Ducting and baffles ensure that the cooling air gets where it needs to go.


    




Compared with the room-oriented architecture, the airflow paths are shorter and more clearly defined with the close-coupled cooling systems. Smaller fans can be used due to lower volumes of chilled air; energy costs are minimized; it is easier to target air onto high-density hot spots for preferential cooling; and business continuity improves, as the failure of any one single unit in the cooling environment only affects that rack or cabinet, as opposed to the total data center or the whole aisle containment. And, as the majority of these systems are modular, it is easy and cost-effective to build in degrees of resilience, leading to higher availability across the whole data center.


About us





Strategic Media Asia (SMA) is one of the approved CPD course providers of the Chartered Institution of Building Services Engineers (CIBSE) UK. The team exists to provide an interactive environment and opportunities for members of ICT industry and facilities' engineers to exchange professional views and experience.

SMA connects IT, Facilities and Design. For the Data Center Design Consideration, please visit 
(3) Cooling,
(4) Redundancy,
(9) Code & Standards, and

All topics focus on key components and provide technical advice and recommendations for designing a data center and critical facilities.


Friday, September 1, 2017

Showroom Tour for the Latest Data Center Efficiency Management and BMS Solutions

Half Day Showroom Tour
Sponsored by APC, Schneider Electric (www.schneider-electric.com)





A BIG THANK YOU to the Schneider Electric's team on 25 August 2017. The latest data center energy saving, cooling solutions, efficiency and data center management systems are introduced and explained during the visit.


  

The BMS (Building Management System) solution integrated with cloud computing and data analysis technology is also demonstrated to our engineers and fellow participants.







Further to the our critical facilities design course, the half-day showroom tour provides an interactive environment and opportunities for the engineers to exchange professional views on mission-critical facilities with a hands-on and immersive experience.







About us





Strategic Media Asia (SMA) is one of the approved CPD course providers of the Chartered Institution of Building Services Engineers (CIBSE) UK. The team exists to provide an interactive environment and opportunities for members of ICT industry and facilities' engineers to exchange professional views and experience.

SMA connects IT, Facilities and Design. For the Data Center Design Consideration, please visit 
(3) Cooling,
(4) Redundancy,
(9) Code & Standards, and

All topics focus on key components and provide technical advice and recommendations for designing a data center and critical facilities.










Monday, July 3, 2017

Join the Technical Visit + CPD Course in Electrical Design for Mission Critical Supply



Electrical Design for Mission Critical Supply (2-day)
(10 - 11 August 2017, approved CPD course by CIBSE UK)


Mission critical facilities have particular power requirements that significantly impact how they are designed and operated. You will gain insight into the critical supply system, from power components to distributions and efficiency; from power requirements to sizing, design, testing and commissioning:


-- Concept on primary supply and secondary supply
-- Power flow in mission critical supply system
-- Features of major equipment for critical supply

> Uninterrupted power supply and power storage
> Backup generator
> Automatic transfer switch
> Static transfer switch
> Isolation transformer

-- Efficiency assessment
-- Power quality review
-- Configuration diagram of critical supply (N+1 / 2N) design & analysis
-- Review of cable sizing to incorporate harmonics content
-- Earthing system design
-- Testing and commissioning requirements
-- Brief of Systems Merging Appraisal Test (SMAT)


The sessions detail about the power system components that support typical data centers or mission-critical infrastructure. It prepares individual to fully understand the high voltage systems' design & build by exploring the international best practices and sharing the instructors' experience.

Speakers' Profile - www.stmedia-asia.com/profile


Date: 10 - 11 August 2017 (Thursday - Friday)
Time: 10:00 – 17:30

Venue: Ground Floor, Innocentre, 72 Tat Chee Avenue, Kowloon Tong, Hong Kong
(Next to the Hong Kong Productivity Council)

Fee: Special rate for CIBSE / HKIE all membership classes
Language: Cantonese (with English Course Materials)

For details, please refer to www.stmedia-asia.com/newsletter_6.html.






Half Day Technical Visit / Showroom Tour

Sponsor - APC by Schneider Electric (www.schneider-electric.com)


Further to the critical facilities design course, a half-day showroom tour is arranged to demonstrate the critical power, cooling facilities and data center management solutions by one of the world’s leading equipment provider. The tour also provides an interactive environment and opportunities for the engineers to exchange professional views on mission-critical facilities with a hands-on and immersive experience.


Date: 25 August 2017 (Friday)
Assembly Time: 15:45 - 16:00
Assembly Point: 11/F, Kerry Centre, 683 King's Road, Quarry Bay, Hong Kong


* Pre-registration required
* Seats are limited. Priority will be given to the CPD course's participants.


Enrollment & Registration

Kindly complete and return an Application Form together with a crossed cheque made payable to “Strategic Media Asia Limited” - Room 403, 4th Floor, Dominion Centre, 43 - 59 Queen's Road East, Hong Kong.


About the Organizer

Strategic Media Asia Limited (SMA) is one of the approved CPD course providers of the Chartered Institution of Building Services Engineers (CIBSE) UK. For details, please visit www.stmedia-asia.com/about.html or http://green-data.blogspot.com (Knowledge Blog).


Adverse Weather Arrangement - Events in the morning, afternoon or evening will be cancelled if typhoon signal No. 8 or above or black rainstorm warning is still hoisted after (or is announced by the Hong Kong Observatory to be hoisted at / after) 6:00 a.m., 11:00 a.m. and 4:00 p.m. respectively. Delegates will be notified when the class will be made up as soon as possible.


P.S. Think your team might also be interested? Pass it on ›


Strategic Media Asia Limited
Connecting IT, Facilities and Design

T (852) 2117 3893 | F (852) 2184 9978

Room 403, 4th Floor, Dominion Centre, 43 - 59 Queen's Road East, Hong Kong
http://www.stmedia-asia.com | http://green-data.blogspot.com