Showing posts with label Data Centre Training. Show all posts
Showing posts with label Data Centre Training. Show all posts

Monday, March 18, 2013

Data Center Design & Critical Facilities - Join the Training Seminar & Event Series




Half Day Event on IT & Critical Infrastructure


ICT technology is widely used in a city’s infrastructure development, such as large scale data centres, building and architectural modelling, optimal electric power generation and distribution and supervisory control and data acquisition of railway and transportation systems. There are more and more stakeholders such as researchers, developers, providers, and applications/users involved in the corresponding technology development.


The half day event aims to provide a forum for government officials, university researchers, and key industry professionals to share with other fellow colleagues the latest ICT technology development and applications, as well as its potential for local ICT industry.


Date: 12 April 2013
Venue: The Hong Kong Productivity Council Building
Organizer: ICT Section of IET Hong Kong and OGCIO, the HKSAR Government


Event Detail: http://www.theiet.org/events/local/175263.cfm



Training Seminars on Data Center Facilities & HVAC Design
Bundled with Data Center Technical Visit on 28 March 2013


Further to the half day event, we introduce critical infrastructure systems that support a typical data center and prepare individuals to fully understand the main components that facilitate data center design & build by exploring the standards of TIA-942 and Uptime Tier levels.


The training seminars explain key challenges and consider different criteria, from design, testing, commissioning, sustainability and efficiency, of HVAC (Heating, Ventilation, and Air Conditioning) system in a data center.


Part I – Data Center Facilities Design and Infrastructure Engineering
Date: 18 – 19 July 2013 (Wednesday - Thursday, 2-day)

Part II – HVAC Design and Cooling Specialist for Data Center
Date: To be announced very soon


Target Audience:
Data Center Operators, Consultants, Facilities Managers, E&M Engineers, IT Management, etc.


Time: 10:00 – 17:30
Venue: 1st Floor, Innocentre, 72 Tat Chee Avenue, Kowloon Tong, Hong Kong
Special Rate: 10% Discount on Registration Fee


Speakers:

C.K. Chan, CEng, MIET, MHKIE, CSME, REW H0 C0
Edmond Fok, CEng, IntPE, MCIBSE, MIFireE, REW H0 C0
Herman Poon, CEng, Eur. Ing., CITP, MBCS, MHKIE
Joe Tang, CEng, MIET, MCIBSE, MASHRAE



Worldwide Accredited Data Center Qualification
Jointly Organised with CNet Training, UK


Certified Data Center Management Professional (CDCMP)
Core Unit (3-day) + Advanced Professional Unit (4-day)
Accredited by BTEC, Edexcel and BICSI


Commencing Date: 19 June 2013


Instructors from UK will lead the whole program:
http://www.cnet-training.com/delivered-by-expert-instructors/


Enrolment & Registration Details


Please refer to our website (www.stmedia-asia.com/trainings.html) or a registration form attached. A data center technical visit (sponsored by KDDI Hong Kong Limited) will be arranged. For detail, please visit www.stmedia-asia.com/data-center-tour.html

Saturday, October 20, 2012

Data Center Site Tour / Technical Visit

Data Center Site Tour / Technical Visit
Data Center Site Tour
Sponsored by KDDI Hong Kong Limited (www.kddi.com.hk)

Overview

Strategic Media Asia (SMA) is pleased to announce that a Data Center Site Tour, organized by KDDI Hong Kong Limited (KDDI), will serve for individuals who successfully attend the training seminars in Data Center Facilities and HVAC Design.

Per normal practices, site tour only reserves for data center its own customers and will not open to the public. Therefore, it is definitely a rare chance for the selected participants from our Training Seminars to visit a world-class Tier 3+ purpose-built data center facility in Hong Kong.

For whoever who are interested in data center business and cooperation, SMA and KDDI will provide extra support to those companies in order to maintain the customers' satisfaction.




KDDI Hong Kong Limited

KDDI Corporation is a Fortune Global 500 companies and Top 10 Telecom Company in the World as of 2012.

Subsidiary company, KDDI Hong Kong was established in Hong Kong in 1988 and has over 20 years of experience in providing the One Stop Information Communications Technology (ICT) Solution to enterprises in Hong Kong such as providing Data Center Services, Content Delivery Acceleration (CDN), end-to-end Global Network, quality ICT Solutions and System Integration.

Through collaborative partnerships, KDDI has built up with telecommunications companies around the world in order to provide both a wide service area with high service quality. KDDI's backbone is a high-capacity fiber network that weaves the world together and its TELEHOUSE, which is an established global data center brand over the world.


For detail, please visit: www.kddi.com.hk





Telehouse Hong Kong CCC

TELEHOUSE HONG KONG CCC is one of the largest and most technologically advanced carrier neutral data center facilities in Hong Kong and in the Asia Pacific Region.

Telehouse Hong Kong CCC is a Tier 3+ purpose-built data center facility is strategically located in Tseung Kwan O, Hong Kong where around 19 km from the Central Business District and approximately 30 minutes from the Hong Kong International Airport. With virtually no risk of natural disasters in the vicinity, TELEHOUSE HONG KONG CCC is ideal for securing mission-critical business systems.

TELEHOUSE HONG KONG CCC service provides multinational corporations and local businesses in Hong Kong with neutral, secure and power-protected co-location facilities. It offers full end-to-end ICT Solutions from design to implementation such as IP connectivity, system integration, LAN and software installation, system monitoring and virtual servers as well as premium data centers.


For detail, please visit: www.telehouseglobal.com


Site Tour Details

Date 12 October 2012 (Full, next round will be arranged in Nov / Dec 2012)
Time 1:45pm - 5:00pm
Meeting Point Exit D, Kowloon Tong MTR Station (To Fuk Road, Transportation is provided)
Target Audience Data Center Operators, Consultants, Facilities Managers, E&M Engineers, Government / Corporates' IT Management, etc.
Fee Waived and Exclusive for Participants of Training Seminars
Enrollment Registration can be made during the training seminars or sent to info@stmedia-asia.com for reservation by 7 days before the Site Tour held
Remark Business Card and HKID Card (or Passport) are required for the on-site registration
Should you have any enquiry, please feel free to contact (852) 3796 3026 / info@stmedia-asia.com. Kindly visit our website (www.stmedia-asia.com) for further information.

General Guideline

- All visitors must submit full name (same as HKID) and working company to SMA for pre-registration
- All visitors must present their HKID and name card for on-site registration
- KDDI's representatives will conduct brief introduction and Q&A section before and after the Site Tour
- KDDI and SMA reserve the right to refuse any unexpected registration for the Site Tour
- In case of disputes, the ultimate decision will be reserved by KDDI and SMA

Courtesy Reminders :

- All visitors must wear and present their visitor passes during the Site Tour
- All visitors must return the visitor passes to the Reception Desk after the Site Tour
- Tour guides will accompany with all visitors during the Site Tour
- Smoking is prohibited
- Food and drinks are prohibited, except for designated dining area
- Photo taking and video recording are prohibited


© 2012 Strategic Media Asia Limited - Where IT, Facilities and Design Meet
T (852) 3796 3026 | F (852) 2184 9978 | www.stmedia-asia.com
Rm 1303, Leighton Centre, 77 Leighton Road, Causeway Bay, Hong Kong

Monday, July 23, 2012

Key Areas to Examine for Data Center Efficiency

Are you struggling on where to start your energy efficiency efforts? Look to these four key areas for improvements.

  • Cooling: Typically the lowest hanging fruit.
  • Water: Don’t overlook the use of water, due to its scarcity in certain areas. Water is related to energy as well.
  • Electrical Design: Recent engineering innovations offer new efficient options.
  • Incentives: Help offset improvement or development costs of energy efficiency.



Measuring Efficiency


Power Usage Effectiveness (PUE) is the most popular industry metric for measuring the energy efficiency of data centers. Today, there appears to be an arms race for the lowest PUE. Even if you aren’t one of the select few with the operational flexibility to participate, you can measure your PUE and work to improve efficiency relative to your own data center site. The industry group, The Green Grid, has many resources available on PUE.

You may also consider to take some data center training / certification - Energy and Cost Management for Data Center.


Green Cooling Techniques


ASHRAE’s latest version of TC 9.9 drastically expanded the recommended and allowable temperature and humidity ranges with the approval of the major server manufacturers. It is estimated that an energy savings of 2-4% can be realized for each degree Celsius the temperature is raised in a data center. It seems raising the temperature is low hanging fruit, but I have seen very few do it to date.

Another undisputed, easy and inexpensive energy saver is hot or cold aisle containment. Preventing the mixing of cold and hot air results in a higher return air temperature that yields an increased efficiency of the cooling system. Many systems exist ranging from hard containment systems to simple refrigerator curtains that you might see in a meat locker. Have a limited budget? Hot or cold aisle containment provides a compelling financial argument for adoption.

Free cooling is now a critical consideration–with either air-side or water-side economization. The new temperature and humidity ranges offered by TC 9.9 make free cooling feasible for a large part of the year in any location, and when designing a new data center or expanding an existing facility.
Liquid cooling has been talked about a great deal of late, with liquids being far more efficient at expelling heat than air. The approach requires some modification of the server so that it can be submerged in the liquid, but studies have shown positive results.

Evaporative cooling is another energy efficient technique, especially applicable in dry climates. However, evaporative cooling often sparks a debate over the use of additional water, especially in water-constrained areas.





Water Efficiency


Water is a topic that is gaining increased attention and will continue to do so in the future. I once heard a “futurist” say that “water is the new oil.” In evaluating evaporative and other cooling techniques, many (myself included) have made the mistake of evaluating only the amount of water used in the respective cooling systems.

In order to determine the complete hydro-footprint of a system, you must also look at energy usage and how much water is used in the production of that energy. The National Renewable Energy Lab (NREL) published a study that analyzed how much water is used in the production of power per kilowatt-hour on a state-by-state basis. While not perfect, it provides a basis for analysis from an authoritative source. After taking the amount of water used in the production of energy into account in a particular geography, evaporative cooling can have a smaller hydro-footprint (use less total water) than a chilled water system due to the amount of energy saved.

There have been a few projects of late that use either sea water or ground water for cooling, which is very efficient as it effectively eliminates the need for much of the cooling equipment. A site in central Nebraska is pursuing this tactic by using irrigation wells with a volume of 1,000 GPM at 52⁰F as the source of groundwater for cooling and re-injecting the water back into the aquifer. This is not only very energy efficient, but uses little to no water for cooling, saving on both capital expenditures (CAPEX) and operating expenditures (OPEX) through the elimination of much of the cooling equipment. The net impact addresses both the energy and water efficiency of the equation for a very energy efficient, and therefore sustainable, cooling solution.


Highly Efficient Electrical Solutions


Major efficiency gains have been made in recent years in electrical equipment that can improve your data centers’ PUE. There are multiple manufacturers of UPS’ that are reaching efficiencies of 96-98 percent at less than 50 percent load. This is important if you utilize A and B feeds to your equipment for redundancy.

Another trend is for the UPS to operate in a by-pass mode, which eliminates the losses through the batteries. Many are not yet comfortable with this mode of operation, but it is another efficiency gain to consider in optimizing performance. Higher voltage and DC power are also evolving trends that provide efficiency gains that bear mentioning.


 


Energy Efficiency Incentives and Rebates


Whether designing a new, energy efficient data center or upgrading your existing facility, there are many incentives available to help defray the cost and improve your ROI.

Power companies are commonly providing incentives based upon your performance compared to a baseline building or a baseline piece of equipment. Plan to include the power company as early in the design phase as possible, to maximize the financial benefits. Some require approval of the incentive prior ordering the equipment.


Additional Considerations


There are additional considerations beyond those mentioned above in optimizing your mission critical facility’s efficiency.
  • System modularity is an accepted practice that affects efficiency. Implementing modular and rapidly expandable designs in lieu of installing full density on day one typically results in higher efficiency through higher equipment utilization. This saves on CAPEX and OPEX, making for a smart business decision.
  • Cogeneration, also known as combined heat and power (CHP), has gained in popularity and can be as high as 60-80% efficient compared to the typical 30% efficiency of normal power plants.
  • Peak power shaving can also be achieved through thermal storage. This is done by creating ice at night when power rates are lower and utilizing the ice for cooling during the day.

Measure, Improve, Monitor and Repeat


Regardless of the selected energy efficiency measures in your new or existing data center, make sure you measure your initial or existing condition so you have a baseline. After your improvements are made, measure again to determine your new condition and your ROI. In the case of a new data center, perform a total cost of ownership (TCO) analysis to guide your decisions. You should continue to monitor your efficiency and make improvements to improve your PUE relative to your initial condition. As a reminder, measuring your outcomes against those in the industry under different operating conditions may not provide an apples-to-apples comparison.

Monday, June 18, 2012

Design & Operate a Data Center for Energy Efficiency

EU Code of Conduct for Data Center Energy Efficiency
2-day Training Seminar on EU Code of Conduct for Data Center Energy Efficiency (2012)
The Best Practices for Designing an Energy Efficient Data Center

Overview

In response to the rising challenges facing data centre operators, owners, systems designers, equipment manufacturers and customers, the European Commission have introduced the Code of Conduct for Energy Efficiency in Data Centres. The Code aims to raise awareness of the issues and opportunities and to recommend best practice solutions. We introduces the Code, the benefits it brings, the levels of commitment required, the technical background to the best practices, data collection and reporting together with real examples.

This 2-day training seminar enables individuals working in data centres to improve cost and energy efficiency. The ongoing development of the Code encompasses topics associated with new data centre planning, design and development, and the tuning and operation of existing facilities.
All sections are conducted by Chartered Engineers (CEng) and help you to approach best practices in designing and operating energy efficient data centers by our further technical programs.

Registration Detail

Date To Be Announced (2-day)
Time 10:00am - 5:30pm
Venue 10th Floor,Central Building, 1 - 3 Pedder Street, Central, Hong Kong
Target Audience CIO, CTO, IT Directors, Data Center Operations / Facilities Managers, Data Center / ICT Consultants and E&M Engineers
Fee Normal Rate: HK$6,500 (Early Bird Rate: 10% Discount)
(Two refreshment breaks will be provided.)
Enrollment Online Registration or Download Application Form
Exam and
Certification
All content cover an accredited syllabus necessary to sit the British Computer Society (BCS) "Intermediate Certificate in EU Code of Conduct for Data Center" exam through Prometric (www.prometric.com). However, taking the course does not offer a guarantee of passing. Extra examination fee required.

Individual CPD / completion certificate can be granted by our experienced Chartered Engineers (Available upon request).
Should you have any enquiry, please feel free to contact us at 3796 3026 / info@stmedia-asia.com

 

Day 1 Content


- Define, identify and list data center best practice sections
- Power distribution in data center - the power tree
- Optimizing the data centre requirements
- Area of responsibilities (physical building, mechanical & electrical plant, data floor, racks, etc.)
- Efficient cooling 1 (hot / cold aisle containment, raised floor, ceiling height, airflow control, etc.)
- Efficient cooling 2 (CRAC settings, arrangement of cable trays, cabinets and cooling plants, etc.)
- Efficient cooling 3 (air free cooling, water free cooling, mechanism of absorption chiller, etc.)
- Interactions and interdependencies of various systems
- Standby UPS
- Standby ferro UPS
- Line interactive UPS
- Double conversion on-line UPS
- Delta conversion on-line UPS
- Temperature and humidity control
- Factors affecting data center energy consumption


Day 2 Content


- Resilience level and provisioning
- Data center efficiency and Uptimes Tier levels requirements
- ASHRAE 2011 common environmental guidelines
- ETSI EN 300 019 Class 3.1
- Select and deploy of new IT equipment
- Data centre utilisation, management and planning (software, IT and M&E)
- Physical building layout (site selection, water sources, use of economizers, etc.)
- Lighting control (EU standards, LEED, BREEAM, etc.)
- Monitoring (energy use & environmental reporting, etc.)
- Items under consideration (rotary UPS, mechanical UPS, etc.)
- Minimum practices for data center energy efficiency
- Metrics used to measure data center energy efficiency


Delivered by Experienced Speakers

Mr. Joe Tang

Having more than 10 years experience in mission critical design, Mr. Tang was working on numerous projects involving data centers, disaster recovery sites, trading floors for multinational financial institutes and data centre providers in Hong Kong, Taiwan, Shanghai, South Korea and India.

He is specialized in the areas of master site planning, mission critical infrastructure design, single point of failure study, cause and effect analysis and integrated system test. Mr. Tang is now working in a multi-disciplines consultancy providing sustainable design and green initiatives to different sections in Asia Pacific.

Mr. Tang is also:

- A Chartered Engineer of Engineering Council (CEng)
- A Member of The Institution of Engineering and Technology (MIET)
- A Corporate Member of Chartered Institution of Building Services Engineering(MCIBSE)
- A Member of American Society of Heating, Refrigerating and Air-Conditioning Engineers (MASHARE)
Ir Joson Chan

Ir Chan had started his career as part-time lecturer since 2001 and has been served in various territory institutes. He majors in teaching subjects in electrical engineering, project management, sustainable engineering and facility engineering for critical services. Ir Chan is a permanent members of CNet Training professional data centre training team.

Ir Chan has gained extensive experience within different aspects of infrastructure projects and as a Senior Engineer in an E&M consultant firm, mainly involved in the data centre / financial institutions MEPF design projects and working with companies such as Morgan Stanley, Deutsche Bank, HSBC, etc. He is now working in an international theme park and resort to maintain facility support of critical facility and Network Communication Centre. He unites learning with this key career experiences, allowing delegates to gain essential insight into real-life working and scenarios.

Ir Chan is also:

- A Chartered Environmentalist (CEnv)
- A Fellow of Society of Operations Engineers (FSOE)
- A Chartered Engineer of Engineering Council (CEng)
- A Member of The Institution of Engineering and Technology (MIET)
- A Corporate Member of the Hong Kong Institution of Engineers (MHKIE)
- Grade H0 and C0 Registration of Electrical Worker of the HKSAR Government
Ir K.T. Poon

Ir Poon has more than 10 years consultancy experience in data center design and build, operation management, energy and cost management projects both in Hong Kong and China. He was also working for a design and installation of a facility management system in an international school in Hong Kong with a subsystem of an energy management system.

Ir Poon is a part time lecturer in various tertiary institutes. He also teaches facility management, business strategic management of the distance learning courses (both degree and master degree) offered by overseas universities.

Ir Poon is also:

- A Corporate Member of the Hong Kong Institution of Engineers (MHKIE)
- A Chartered Member of the British Computer Society (MBCS)
- A Chartered Engineer of the Engineering Council, U.K. (CEng)
- European Engineer of the European Federation of National Engineering Associations (Eur. Ing.)
- A Chartered Information Technology Professional of the British Computer Society (CITP)

Recent Participants Come Form...

Airport Authority Hong Kong Fujitsu Hong Kong Limited
Asia Satellite Telecommunications Ltd Johnson Controls Hong Kong Limited
Citic Telecommunication CPC Group Leigh & Orange Limited
CTM (Macau SAR) Meinhardt (Hong Kong) Limited
EMSD, HKSAR Government Mizuho Corporate Bank Limited
Elixir International Limited Sociedade De Jogos De Macau
Facilities Analysis & Control Limited Welcome Air-Tech Limited
And More...

© 2012 Strategic Media Asia Limited

T (852) 3796 3026 | F (852) 2184 9978 | www.stmedia-asia.com
Room 1303, Leighton Centre, 77 Leighton Road, Causeway Bay, Hong Kong


Tuesday, June 5, 2012

Green Data Center Engineer Certification Program - Organized by The Society of Operations Engineers (SOE, Hong Kong Region)



The Green Data Center Engineer Certification Program
4 – 20 July 2012

Introduction

In the 2011-12 Policy Address and the 2012-13 Budget, the Government will thoroughly support the conversion of industrial buildings into data centers and the accommodation of data centers in Tseung Kwan O which attract capital investment from global institutions. SOE, who expertizes in mission critical facility / services, supports the policy and first launches a comprehensive program for Green Data Centre in Hong Kong.

The certified program provides a technical knowledge and “green theory” for engineers who are involved in creating sustainable and energy efficient data centre (E&M) / plants or exploiting the role of telecommunication in helping deliver green operation and business practices to other areas of organization such as Tendering & Procurement. It also introduces other efficiency metrics and international standards such as PUE/DCiE (The Green Grid Energy Measuring Tools), Carbon Footprint, TPL accounting, end-to-end life cycle cost, TCO, etc.

Program Outline

(1) Introduction of Green Data Centre
(2) Concepts and trends of Green Data Centre
(3) SWOT analysis of Green Data Centre
(4) Green elements and Risk Analysis of Green Data Centre
(5) Green Implementation Plan
(6) Building a Green Data Centre team
(7) Evaluation life cycle cost for Green Data Centre
 
Speakers:     Ir C.K. Chan, CEng, CEnv, FSOE, FIplantE, MIET, MHKIE, CSME, REW H0 C0
                     Ir Herman Poon, CEng, Eur. Ing., CITP, MBCS, MHKIE

Venue:          Society of Operations Engineers (Hong Kong Region)
                     Unit 2, 3/F, Winsum Industrial Centre,
                     588-592, Castle Peak Road, Cheung Sha Wan, Kowloon, Hong Kong
Date:            4, 6, 9, 13, 16, 18, 20 July 2012 (Monday, Wednesday and Friday)

Time:            7:00pm - 10:00pm
 
 
Registration Fee and Certification Detail 


 
HK$4,000 (Member) and HK$4,500 (Non-Member) including course materials, course assessment and certification

 "Green Data Centre Engineer" certificate will be awarded for those participants who completed the course assessment OR CPD certificate will be issued to students with attendance over 70%. Green Data Centre Engineers are eligible to enroll higher level courses by SOE.

 Please contact Ms. Connie Mui at 3188 0062 or email: connie@soe.org.hk OR download the pdf file for registration -  http://www.soe.org.hk/pdf/11062012/11062012a.pdf


Thursday, May 17, 2012

Data Center Facilities Design & Infrastructure Engineering

Data Center Design and Infrastructure Engineering
Two-day Workshop for Data Center Design (TIA-942 and Tier Standards), Cooling & IT Strategies

Overview


The workshop is designed for executive and data centre owners, managers and operators to enrich their relevant knowledge in data center E&M and facilities management. We provide an introduction of the critical infrastructure system that supports typical data centres and environments. It also prepares you to fully understand the main components that facilitate data centre design & build, operation and management by exploring the standards of TIA 942 and Tier.

All sections are conducted by Chartered Engineers (CEng) and help you to approach best practices in designing and operating energy efficient data centers by our further technical programs.

Registration Detail

Date 26 & 27 October 2012 (Friday - Saturday, 2-day)
Time 10:00am - 5:30pm
Venue 10th Floor,Central Building, 1 - 3 Pedder Street, Central, Hong Kong
Target Audience CIO, CTO, IT Directors, Data Center Operations / Facilities Managers, Data Center / ICT Consultants and E&M Engineers
Fee Normal Rate: HK$4,700 (Early Bird Rate: 10% Discount)
(Two refreshment breaks will be provided.)
Enrollment        Online Registration or Download Application Form (Attached)
Should you have any enquiry, please feel free to contact us at 3796 3026 / info@stmedia-asia.com


Day 1 Content


- Data Centre Overview and Definition
- Data Centre Standards (TIA and Tier)
- Data Centre Network and Structure
- IT Strategy
- Cabinet Layout
- Raised Floor System
- Telecommunication Backbones, Redundancy, Sizing and Planning
- Fiber and Optical System Design
- Fiber and Optical Cable Components
- Copper System Design and High Speed Ethernet

Day 2 Content


- Copper Cabling Components
- Cable Distribution, Layout and Management
- Cooling - Cooling Topologies, Chiller, CRAC, Cooling Towers, Hot / Cold Aisle, etc.
- Power - High / Low Power, Switch System, UPS, Transformers, Fuel Tanks, Generators, etc.
- Earthing / Grounding and Bounding
- Electromagnetic Interference / Electromagnetic Pulse (EMI / EMP)
- Environmental Management System (EMS)
- Fire Protection System
- Physical Security



Delivered by Experienced Speakers

Mr Joe Tang

Having more than 10 years experience in mission critical design, Mr Tang was working on numerous projects involving data centers, disaster recovery sites, trading floors for multinational financial institutes and data centre providers in Hong Kong, Taiwan, Shanghai, South Korea and India.

He is specialized in the areas of master site planning, mission critical infrastructure design, single point of failure study, cause and effect analysis and integrated system test. Mr Tang is now working in a multi-disciplines consultancy providing sustainable design and green initiatives to different sections in Asia Pacific.

Mr Tang is also:

- A Chartered Engineer of Engineering Council (CEng)
- A Member of The Institution of Engineering and Technology (MIET)
- A Corporate Member of Chartered Institution of Building Services Engineering(MCIBSE)
- A Member of American Society of Heating, Refrigerating and Air-Conditioning Engineers (MASHARE)
Ir Joson Chan

Ir Chan, a holder of Bachelor of Building Services Engineering, has endorsement units in Technical Services and Power Electronics, holds an Endorsement Certificate in Air Conditioning and Refrigeration, a Higher Certificate in Electrical Engineering, a Certificate in Electrical Engineering and is an Environmental Officer.

He has gained extensive experience within different aspects of infrastructure projects and as a Senior Engineer in an E&M consultant firm, mainly involved in the data centre / financial institutions MEPF design projects, working with companies such as Morgan Stanley, Deutsche Bank and HSBC to name a few. He unites learning with this key career experiences, allowing delegates to gain essential insight into real-life working and scenarios.

Ir Chan is also:

- A Fellow of Society of Operations Engineers (FSOE)
- A Chartered Engineer of Engineering Council (CEng)
- A Member of The Institution of Engineering and Technology (MIET)
- A Corporate Member of the Hong Kong Institution of Engineers (MHKIE)
- Grade H0 and C0 Registration of Electrical Worker of the HKSAR Government
Ir K.T. Poon

Ir Poon has more than 10 years consultancy experience in Data Center design and build, operation management, energy and cost management projects both in Hong Kong and China. He was also working for a design and installation of a facility management system in an international school in Hong Kong with a subsystem of an energy management system.

Ir Poon is a part time letcturer in various tertiary institutes. He also teaches facility management, business strategic management of the distance learning courses (both degree and master degree) offered by overseas Universities.

Ir Poon is also:

- A Corporate Member of the Hong Kong Institution of Engineers (MHKIE)
- A Chartered Member of the British Computer Society (MBCS)
- A Chartered Engineer of the Engineering Council, U.K. (CEng)
- European Engineer of the European Federation of National Engineering Associations (Eur. Ing.)
- A Chartered Information Technology Professional of the British Computer Society (CITP)

Recent Participants Come Form


Airport Authority Hong Kong Facilities Analysis & Control Limited
Asia Satellite Telecommunications Limited Fujitsu Hong Kong Limited
Citic Telecommunication CPC Group Johnson Controls Hong Kong Limited
Electrical & Mechanical Services Department, HKSAR Government Leigh & Orange Limited
Welcome Air-Tech Limited

And More...

© 2012 Strategic Media Asia Limited

T (852) 3796 3026 | F (852) 2184 9978 | www.stmedia-asia.com
Room 1303, Leighton Centre, 77 Leighton Road, Causeway Bay, Hong Kong

 

Friday, February 17, 2012

EU Code of Conduct for Data Centers, A Toothless Guard Dog?


The EU Code of Conduct for Data Centres, as a practical set of guidelines designed to improve energy efficiency within the data centre industry, bringing vendors and data centre operators together and developing good practices for reducing the energy consumption of data centres, has now made up 12 percent of data centre expenditure.

Few Adopters?


The code is voluntary, and has faced persistent criticism over the small number of organisations that have publicly embraced it. Some have argued that unless more people adopt it, it may have to be embodied in mandatory regulations.

However, according to, Zahl Limbuwala, the Chairman of BCS-Data Centre Specialist Group, the code’s best practices have had not just a significant impact in the EU but much further afield also.

"There are very few data centre people in the EU now that have not heard of the code and most speak positively of it’s goals and effect on the industry."

"Telecity group are one data centre operator that has proven implementing the code’s best practices has made and continues to make good business sense!"

The code was never about regulation or legislation or about forcing businesses to comply, it’s was about making an impact on the ever growing use of energy to ensure it gets used efficiently rather than wasted.

For more green data center training and technical seminars in Hong Kong, please visit http://www.stmedia-asia.com/trainings.html


Friday, January 27, 2012

Buildings Energy Efficiency Ordinance

Buildings Energy Efficiency Ordinance in Hong Kong Enchances the Energy Efficiency in Buildings

The Building Energy Efficiency Ordinance (Cap. 610) will come into full operation on 21 September 2012. The purpose of this ordinance is to enchance the energy efficiency in buildings by means of regulating the building services installations including lighting, electrical, air-conditioning and lift & escalator installations of prescribed buildings in new construction and in major retrofitting works to comply with the minimum energy efficiency standards and requirements specified in Building Energy Code (BEC). Moreover, the Ordinance also requires the central building services installation in commercial building and in a portion of a composite building that is for commercial use to conduct the energy audit in accordance with Energy Audit Code (EAC) in Hong Kong.

Data centers consume large amounts of energy and require many investments of significant financial resources to continue operations. To facilitate data center professionals fulfill the requirements of the Ordinance, Strategic Media Asia (SMA) has recently launch a series of technical seminar in Energy Efficient Data center and Green Data Center Design which cover general data center design standards, TIA-942 and Tier, Facilities Management (E&M) System, EU Green Data Center Design Standard, Data Center Cost and Energy Management. For more training and event detail, please visit www.stmedia-asia.com/events.html

 




Wednesday, January 4, 2012

Modular Data Centers Make Business and Environmental Sense


Pre-engineered and prefabricated data centers now make environmental and economic sense, according a report by environmental IT research consortium The Green Grid.

According to Deploying and Using Containerized/Modular Data Center Facilities, this new modular approach to the construction and deployment of a data centers can be rapidly deployed, have lower operating and capital costs, and be equipped with higher density and energy-savings targets than those data centers built using traditional methods.

As such buildings are pre-designed with energy efficiency in mind they often come equipped with a host of energy and money saving features, the report says. For instance, pre-fabricated data centers often have their heat loads closer to their cooling coils and are designed to handle wider temperature and humidity bands than other data centers, according to the report.

As modular data centers can be constructed faster than traditional ones, upfront capital costs can be reduced as well. Rather than build a center designed to handle whatever capacity may be needed in the future, companies using prefabricated data centers can expand the facility as and when increased capacity is required, the report says.

In October, it emerged that Allianz Global Investors of America was using IO’s IO Anywhere modular data center system.

Allianz said that by using the system it hoped to avoid the upfront commitment of a multiple megawatt power plan, resulting in significant operating and capital expense savings.


Adopted from http://www.environmentalleader.com

Strategic Media Asia (SMA) provides any data centre and IT professionals with top level understanding of best practices in energy efficient data centre management from a series of accredited certificate courses and training seminars which focus on international green standard, financial and regulatory, facilities management, hardware management and software / system networks of Data Centre. For more informaiton, please visit the Program Page.

Monday, December 19, 2011

Increase in Power Bill Raise The Importance of Energy Efficient Data Center

In Hong Kong, China Light and Power (CLP) has asked the government for permission to raise the Power Bill by 9.2 percent next year in 2012, whereas Hongkong Electric (HKE) demanded a 2.64 to 6.08 percent fee hike. The increases requested by both power companies far exceed the rate of inflation. They will add considerably living expenses to residental customers and operation costs to businesses which require large amount of power and energy consumptions.


Adopted from South China Morning Post (SCMP)

Data centers, which come in different sizes and provide mission critical functions for most businesses, consume large amounts of energy and require many investments of significant financial resources to continue operations. Despite of the high demand of data centre in Hong Kong, many organizations are looking for new ways of doing more with less, reducing IT budgets or curtailing the incidental costs associated with data center operations and even expansion.

Saving Energy Consumption and Power Bill

Data center efficiencies can be attained through increasing compute densities, creating cold aisle containment systems or more effective use of outside air, but the key component over time is to have an easily understood metric to gauge data center efficiency, and how much improvement is taking place.

Strategic Media Asia (SMA), which is vendor independent and accredited by British computer Society (BCs), provides data centre and IT professionals with top level understanding of best practices in energy efficient data centre from a series of certificate courses and training seminars focusing on international green standard, financial and regulatory, facilities management, hardware management and software / system networks of Data Centre.
Completion of the accredited courses and examinations will be awarded 3 certificates granted by BCS:

Foundation Certificate in Green IT
Intermediate Certificate in EU Code of Conduct in Data Centre
Intermediate Certificate in Energy & Cost Management in Data Centre

The 3 certificates equips you and your team and data centre to apply for
Certified Energy Efficient Datacentre Award (CEEDA)

We aim at teaching several aspects: (1) Data Centre Utilization (2) Data Centre Facilities (3) Cooling (4) Power Equipment (5) Data Centre Cost Savings (6) Monitoring. Each unit is principally assessed by examinations that lead you through all the steps needed to arrive at a baseline of a modern green data centre and energy saving.

Furthermore, we bring you a unique opportunity to learn from our lecturers and apply the knowledge immediately to your own facility with assistance from our experts. An additional on-site audit services for your own data centre with full audit report can help you achieving the criteria of best practice design and energy efficient in data centre after the series of training programmes.


Target Audience

Data Centre and Facilities Managers
Data Centre Operators
Data Centre Design Consultants
Data Centre Technicians and Engineers
Sales Engineers from OEM Vendors
CSR / Environmental Champions in technology departments
IT Purchasers (Hardware & Software)
IT Architects and Solution Consultants

For more information, please contact (852) 3796 3026 or download our Training Event's Brochure.

Monday, December 12, 2011

PUE & Cost Savings - Why go Green?

PUE and other efficiency measures on data centre are useful, but we more likely chasing the money now!
Efficient data centres have always made an effort to meet commercial needs – but the economic side of the movement may soon eclipse the “green” side, environmental issues and corporate image.

The move to the cloud is driving this. “Cloud-based services [like Facebook and Google], have the ability to build efficient data centres in locations where there is cheap power, and to highly utilise the IT equipment,” said Mark Monroe, executive director of the The Green Grid. “Their primary function is to drive the cost of a transaction down as low as it can be.”

The Green Grid has just had its annual European conference, over two days in Paris and London, and is reacting to this world, where it is all about the lowest cost for transactions. “Amazon can deliver a CPU-hour, for 10 cents,” said Monroe. He would have delivered the same measure for $3.75, two years ago, when he worked on Sun’s sustainable data centres.

It’s more about the money than the tech

The Green Grid has been known for the PUE measure of effiency, which has been picked up by various interantional bodies, and is regularly quoted for any new efficient data centre development.
At first sight, its other work looks like a continuation of that sort of effort, providing yet more ways for centres to measure their performance and compare themselves, including the still-under-development CUE and WUE measures of carbon-usage and water-usage respectively.

But alongside these measures, the group is coming up with a wide range of other material, which is increasingly designed to look hard-nosed, practical and, let’s face it, commercial.

Saving money, not PUE

The latest Green Grid White Paper surveyed members’ use of economisers, the cooling system which offers free air cooling and replaces the use of chillers.  Economisers trumpeted as a way to improve PUE. According to the survey, however, they do improve efficiency, but have no discernible effect on PUE.

“There was no statistically significant difference between the PUE reported by those who use economizers and by those who do not,” the report found.

They are taking off rapidly amongst Grid members, however, they save money. Around half the members surveyed are using economisers, and they are using them for almost all the hours allowed by the local climates (which turns out to be around 4,000 hours). They are doing so, because they are saving money – around 20 percent of the energy bill, with a payback time of around 20 months, according to Monroe.

Training program and Best Practices in Energy and Cost Savings for Data Centre

The British Computer Society is now launching an advanced certificate in Energy and Cost Savings in Data Centre. Strategic Media Asia is an Approved Training Provider in Hong Kong which is qualified to deliver such professional certificate training programme with Chartered Engineers (CEng). For more information and detailed syllabus, please contact (852) 3796 3026 or download brochure here.

Tuesday, December 6, 2011

The First Well-structured Green Data Centre Trainings in Hong Kong

Get ready to become a data centre energy specialist and prepare for an international data centre award in energy efficiency - CEEDA

Today, many organizations are looking for new ways of doing more with less, reducing IT budgets or curtailing the incidental costs associated with data center expansions. And data center managers need to focus on creating efficient operating environments to augment the life of existing data centers. Data center efficiencies can be attained through increasing compute densities, creating cold aisle containment systems or more effective use of outside air, but the key component over time is to have an easily understood metric to gauge data center efficiency, and how much improvement is taking place.

StrategicMedia Asia (SMA) provides any data centre and IT professionals with top level understanding of best practices in energy efficient data centre management from a series of 3 accredited certificate courses and training seminars (below) which focus on international green standard, financial and regulatory, facilities management, hardware management and software / system networks of Data Centre.

 Data Centre Facility and Infrastructure Engineering

The section is fundamental for executive and data centre owners, managers and operators to enrich their basic knowledge beyond the industry jargons and terminology. We provide a general introduction of the critical infrastructure system that supports typical Data Centres and environments. It also prepares you to fully understand the main components that facilitate Data Centre design & build, operation and management.

Green IT

The training provides a fundamental qualification for ICT engineers who are involved in creating sustainable and energy efficient data centre or exploiting the role of IT in helping deliver sustainable ICT operation and more efficient business practices to other areas of the organization. It also introduces different Green Standards such as ISO 14000 Series (Energy Measurement), Energy Star and PUE / DCiE (From The Green Grid).

Energy and Cost Management in Data Centre

This section explicitly deals with an organization's strategy as it relates to the effective use of energy by software, ICT systems and support infrastructure (mechanical and electrical systems) within the data centre. It will impart an understanding of the use and cost of energy in data centres with an appreciation of the contributing factors, awareness of best practices at a high-level and strategies to control and manage energy consumption and cost in data centres. Key area include:

Cost & Energy Monitoring and Reporting in Data Centre
How to Manage Energy and Cost
Interdisciplinary Teams’ Interactions and Communications
Energy Management and Energy Performance Efficiency
Efficiency Metrics
Metering
Reporting Energy and Carbon e.g. for CRC
Reporting Cost - The challenge of per cost accounting
The Roles for -
Estate Management, Facilities Management, Data Centre Manager,
IT Management, IT Analysts, Business Management


EU Code of Conduct in Data Centre

The training will impart an understanding of the purpose of the EU Code of Conduct and how to apply the Code's best practices at a high-level as well as helping you to develop a common language around energy efficiency. Key area include:

The reason of implementing best practice in the Code of Conduct
The bodies who use the EU Code of Conduct
Energy Measurement and Metrics
Best Practice - Interactions and Interdependencies
Best Practice - In detail

- Data Centre Utilization, Management and Planning
- IT Equipment and Services
- Cooling
- Data Centre Power Equipment
- Other Data Centre Equipment
- Data Centre Building
- Monitoring
- Practices to become minimum expected
- Items under consideration

Monday, December 5, 2011

Green Data Centre Remians Hot in next 5 to 10 years

Companies are beginning to focus more on implementing systems that will reduce their energy expenses and carbon emissions, according to a study by Pike Research.


Enterprises’ investment in environmentally-friendly data centre systems will grow sharply over the next ten years, rising to represent 28 percent of the total data centre market.

In a change from the past, companies are now focused on implementing systems that will reduce their energy expenses and carbon emissions. As a result, global revenues associated with green data centre technologies will grow from $7.5bn (£4.3bn) to $41.4bn by 2015. That increase is partly due to greater awareness of the financial benefits of greater efficiency and Corporate Images (CSR, Corporate Social Responsibility).

The cost of energy has seldom been a concern for IT departments in the past and there was little incentive to invest in energy efficiency improvements. However as data centre energy costs become more visible, the financial benefits of moving to a green mode of operation are being recognised by CEOs, CFOs and CIOs.


Green Transformation


The change is part of a broader shift in data centre technology, which is seeing the growing use of adaptable technologies such as virtualisation. This change is also shifting the way data centres are designed and the relationship between IT and business sides of organisations.

Power and cooling, still, are key issues and make up the largest proportion of the green data centre market segment, making up 46 percent of the segment’s revenues by 2015, according to the study. The second-largest category will be energy-efficient IT equipment, accounting for 41 percent of the market segment, and monitoring and management equipment for Auditing, with 14 percent, according to the “Green Data Centres” report.

Adopted from www.eweekeurope.co.uk


Saturday, December 3, 2011

Green Data Centre Best Practices Translated into Energy and Cost Saving

Data Centres come in different sizes - whether it's four servers in a closet or hundreds of servers in a building - they provide mission critical functions for most businesses. Meanwhile, Data Centres consume large amounts of energy and require the investment of significant financial resources to continue operations. In recent years, the Data Centre management professionals have begun to focus on ways to minimize energy consumption and overcome emission challenges. More importantly, the findings tell us that sustainable practices can be translated into financial savings.

Strategic Media Asia (SMA) is vendor independent and professional training provider, which is currently accredited by BCS, The Chartered Institute for IT, in green data centre qualifications in Hong Kong. The green program provides you with top level understanding of best practices in energy efficient data centre management from a series of 3 accredited certificate courses and training seminars which focus on international green standard, financial and regulatory, facilities management, hardware management and software / system networks of Data Centre.

(1) Green IT (3-day, accredited by British Computer Society)
(2) EU Code of Conduct in Data Centre (2-day, accredited by British Computer Society)
(3) Energy and Cost Management in Data Centre (3-day, accredited by British Computer Society)


PLUS 2-day training seminar on "Fundamentals of Data Centre Facility and Infrastructure Engineering" organized by SMA at the beginning of 3 certificate courses.

The Green Data Centre Training Framework

Completion of the accredited courses and examinations will be awarded 3 certificates granted by BCS:

Foundation Certificate in Green IT
Intermediate Certificate in EU Code of Conduct in Data Centre
Intermediate Certificate in Energy & Cost Management in Data Centre



The 3 certificates equips you and your team and data centre to apply for
Certified Energy Efficient Datacentre Award (CEEDA)


SMA aim at teaching several aspects: (1) Data centre utilization (2) Data Centre Facility (3) Cooling (4) Power equipment (5) Data centre building (6) Monitoring. Each unit is principally assessed by examinations that lead you through all the steps needed to arrive at a baseline of a modern green data centre and energy saving.